Fixed step size

Please reach out: support@ecotron.ai if your questions didn’t get replied.
Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #2251

    trucker
    Participant
    • heavy duty truck company

    When combining EcoCal with Simulink, the Fixed step size/basic sample time in the solver screen of Simulink is always reverted to 0.001 sec although some other setting such as 0.01 sec are selected. How can I set the fixed step size/basic sample time of Simulink to 0.01 sec which is our desired setting?

    #2267

    Terry Xu
    Keymaster
    • Ecotron

    Hi there,

    Will you use EcoCoder v2.9.6R5?

    In versions before V2.9.6R1, Fixed-step can only be 0.001, but in versions after V2.9.6R1, Fixed-step can be modified.It supports 0.001, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, and 0.5 if the selected target is MCU, and any value if the selected target is EcoCoderAI

    Thanks!

    #2268

    trucker
    Participant
    • heavy duty truck company

    Thank you for your reply and we understand it.

    Btw, I can only find the EcoCoder manual linked below:
    https://ecotron.ai/Public/EcoCoder%20Manual%20_4.9.2.pdf

    Could I have the latest one? Ver.4.9.2 was last updated on 1/28/2021.

    #2271

    Terry Xu
    Keymaster
    • Ecotron

    Sure, we will send you the latest version via e-mail.

    Thanks for your supporting to our forum.

Viewing 4 posts - 1 through 4 (of 4 total)